06-16-2014 05:47 AM
With this scheme a spawn error -200428 Value passed to the Task/Channels In control is invalid. The value must refer to a valid task. When i add block DaqmxBaseCreateTask.vi before DaqmxBaseCreateChannel.vi spawn new error -200220 Device identifier is invalid. In Measure&Automation Explorer my device is named NI PCI-6036E "Dev1". My system: WinXP, LabView 2013 with Runtime Engine and DAQmxBase and DAQmx 9.5.1 drivers.
06-16-2014 07:17 AM
06-16-2014 07:21 AM
In menu Measurement I/O and DAQmxBase -> not all VI available.
06-16-2014
07:36 AM
- last edited on
11-14-2024
11:08 AM
by
Content Cleaner
Install a version of DAQmx that supports LabVIEW 2013 - 9.8 or later.
https://www.ni.com/en/support/downloads/drivers/download.ni-daq-mx.html#288377
06-16-2014
07:46 AM
- last edited on
11-14-2024
11:09 AM
by
Content Cleaner
On this page: http://www.ni.com/white-paper/6910/en/#eseries for WindowsXP and 6036E recommended driver is version 9.5.1mx.
06-16-2014
07:54 AM
- last edited on
11-14-2024
11:09 AM
by
Content Cleaner
@Ivan99b wrote:
On this page: http://www.ni.com/white-paper/6910/en/#eseries for WindowsXP and 6036E recommended driver is version 9.5.1mx.
But that version doesn't support LabVIEW 2013. So if you want to use that card, you will need to go to an older version of LabVIEW. Looks like LabVIEW 2011 is the latest version that DAQmx 9.5.1 will support.
06-17-2014
12:09 AM
- last edited on
11-14-2024
11:09 AM
by
Content Cleaner
Send me link to download on LabView 2011, i see this page and not found 2011 version: http://search.ni.com/nisearch/app/main/p/ap/tech/lang/ru/pg/1/sn/n8:28,ssnav:pdl/
06-17-2014 12:29 AM
06-17-2014 03:23 AM - edited 06-17-2014 03:24 AM
Thanks, i install the DAQmx 9.9 driver and change VI in scheme from DAQmxBase to DAQmx and scheme is works. Now i need to upgrade scheme:
1. Scheme must save waveform oscilloscope data to any format.
2. Waveform must be scaled on Plot X or Plot X is must tune scaled.
3. Waveform must be stopped and fixed on Graph.