02-10-2012 06:06 PM
Hello everyone,
I'm currently using PCIe-6323 to acquire analog input signals from 4 MKS Mass Flow Meters model 179A using DAQ assistant (4 channels, 0-5V Differential, 1 sample on demand)
Analog output signals are generated using PCI-6723 and sent to 4 MKS Mass Flow Controllers model 1479A using DAQ Assistant (4 channels, 0-5V RSE, 1 sample on demand) to control air flow rates.
Both PCIe-6323 and PCI-6723 use CB-68LPR terminal block connectors as accessories.
Here's my question/dilemma...
Any thoughts on why or what is happening? Am I missing a step here? Any help is appreciated.
Thanks.
vjm
02-13-2012 12:00 PM
Hello vjm,
It looks to me your are experimenting ghosting, please take a look at the link below:
How Do I Eliminate Ghosting From My Measurements?
Regards,
Mart G