08-08-2011 06:44 AM
Hi All,
I've got a NI DAQ 6501 working well.. However, now I would like to use the serial port capability on the DAQ 6501. I double-checked the software installation in MAX, and I do have Visa & NI-Serial installed. When I look at the cFP-2120 in Max, I see the LED's, some assorted inputs, dipswitches, but not one of the serial ports.is working.
Can you please suggest in this regard.
Thanks,
Sandhya
Solved! Go to Solution.
08-08-2011 07:27 AM
I think you may be a bit confused about the capabilities of the 6501. It's a digital I/O device that connects over USB. I don't think it has anything to do with RS-232.
08-08-2011 07:29 AM
On the other hand, your 2120 has 3 RS-232 and 1 RS-485. Post your code for those and someone here can probably help you out.
08-08-2011 07:34 AM
Serial ports on the cFP-2120 will not appear in MAX. The reason is that none of the cFP controllers are capable of running NI-VISA Server.