LabVIEW

cancel
Showing results for 
Search instead for 
Did you mean: 

Conversion of Dynamic data to waveform double

Solved!
Go to solution

I am trying to calculate HIlbert transform of a of filtered system.The problem I am facing is conversion of Dynamic data to waveform double. I have attached a VI that shows the broken wire. Please someone help me fixing the problem.

0 Kudos
Message 1 of 3
(11,279 Views)
Solution
Accepted by naseera

In the Signal Manipulation Palette (right-click on a Dynamic Wire and look at the right-click options), choose "From DDT" (an apt name -- I think Dynamic Data Wires are a form of poison) and Follow the Directions.

 

Bob Schor

0 Kudos
Message 2 of 3
(11,214 Views)

So Stupid of me

Yeah I tried using that but I was using output as 1D Array of scalar and didn't look at other options. Just figured out these blocks have option of Single waveform as an output.

Thanks for replying and helping

0 Kudos
Message 3 of 3
(11,192 Views)