DAQmx 8.8 not exporting channels

Hmmm. Thanks for responding Dennis. As shown in my capture, I obviously have scales, but export doesn't see them...
Richard






0 Kudos
Message 11 of 22
(1,754 Views)
Strange. What does the initial screen look like where it says 'Welcome to Configuration Export Wizard'? Mine says that the wizard exports configuration data for DAQmx 8.8, NI-488.2, and NI-VISA 4.4.
0 Kudos
Message 12 of 22
(1,746 Views)

Yep, mine says the same thing, plus NI-Motion.

Another thing I just noticed was, when I check the ..By Product button, it says I have 0/0 DAQmx, even through it shows DAQmx. I can click it, but nothing happens, and I can't make an export based on clicking that one button.

Richard






0 Kudos
Message 13 of 22
(1,724 Views)
That is the same as I was getting.
0 Kudos
Message 14 of 22
(1,709 Views)

What version of MAX are you guys working with? I'm working with 4.5.1 and am not seeing that same problem. Installing the latest DAQmx or NI-VISA will reinstall the latest version of MAX.

 

 

ColeR
Field Engineer
0 Kudos
Message 15 of 22
(1,701 Views)

_Bryan wrote:
That is the same as I was getting.

 

Bryan,

 

Did you ever get any resolution to this?

 

Richard






0 Kudos
Message 16 of 22
(1,585 Views)

Have you tried untitled.PNG

 

You could always save this to a global and rewrite them


"Should be" isn't "Is" -Jay
0 Kudos
Message 17 of 22
(1,577 Views)
Thanks Jeff. Yes, there are work arounds, but it's no substitute for the button working in the software.
Richard






0 Kudos
Message 18 of 22
(1,575 Views)

Broken Arrow wrote:
Thanks Jeff. Yes, there are work arounds, but it's no substitute for the button working in the software.

True-  It sounds like you should reinstall DAQmx.  If the LabVIEW hooks work and the MAX functionallity is missing its gotta be a corrupted file somewhere.  The point of trying the LabVIEW functions was meant to point toward the offending API that is not playing nice.


"Should be" isn't "Is" -Jay
0 Kudos
Message 19 of 22
(1,564 Views)

Sorry to say, not yet.

 

I am actually dealing with tech support right now dealing with this.  They did tell me a work around that kind of works.

 

If you go to C:\documents and settings\all users\application data\national instruments\max and copy that directory to a new machine there is a chance it will be recognised on the new machine.

 

I had a motherboard die and the above seemed to work.  But I cannot export the data from the new machine either.  So I am waiting for a response from the support guys.

0 Kudos