LabVIEW

cancel
Showing results for 
Search instead for 
Did you mean: 

Get Volume Info.vi causes LV RT crash on PXI-8106 Controller

The attached VI is causing my PXI-8106 Controller to crash and reboot when I input "c:\" as the path.  I've noticed that if I don't wire up the "Sector Size" output it does not crash.

 

Is this a bug? 

 

Download All
0 Kudos
Message 1 of 3
(3,132 Views)
I reported the same issue on another RT platform, the Compact FieldPoint.  It has been assigned CAR 125607.
0 Kudos
Message 2 of 3
(3,123 Views)

Everyone-

 

            This is unfortunately still a bug in LabVIEW 8.6 but R&D are working on a fix for the next release. I don't know when the next release will be (don't ask :)) but I have a hunch that this bug will be fixed by then. Unfortunately the only work around till then is just to not wire the Sector Size output. Good luck guys and thanks for the feedback. It really does help make LabVIEW better.

0 Kudos
Message 3 of 3
(3,108 Views)