When I go to open my main VI it is unable to find several Sub VI's, but the missing Sub VI's are supposed to be installed with NI-DAQmx which is installed. Some of the missing Sub VI's include 'DAQmx Read', 'DAQmx Start Task', 'DAQmx Stop Task' as well as a few others. I have tried to open the VI using both LabView 2013 and 2014 and have had the same problem with both. Any help is appreciated.

0 Kudos
Message 1 of 4
(3,260 Views)
Solution
Accepted by topic author jyan94

Did you install DAQmx after installing LabVIEW?

Did you select LabVIEW support when installing DAQmx?

0 Kudos
Message 2 of 4
(3,254 Views)
And verify that the version of DAQmx is compatible with your version of LabVIEW. You didn't provide this vital information.

http://digital.ni.com/public.nsf/allkb/B0D5630C0A50D5C6862578E800459248
0 Kudos
Message 3 of 4
(3,246 Views)

I re-installed the DAQmx software and included the support and that did the trick. Thank you Altenbach

0 Kudos
Message 4 of 4