On a E-series DAQ DEvice with two counters how to generate a finite pulse train and continuously read it ( Counts) too

On a E-series DAQ DEvice with two counters how to generate a finite pulse train and continuously read it ( Counts) too
0 Kudos
Message 1 of 3
(2,688 Views)
Generating a finite pulse train requires two counters. One counter is configured to generate a continous pulse train and the other counter gates the counter generating the pulse train to make it a finite generation. Therefore, if you have an E Series device, you will use both of your counters to generate the finite pulse train. Use the 'Finite Pulse Train (DAQ-STC).vi' shipping example in LabVIEW as a reference.
0 Kudos
Message 2 of 3
(2,687 Views)
That is fine but how to count the number of pulses continuously. I have seen the example VI and that does not answer this question.
0 Kudos