02-02-2006 02:42 PM
02-03-2006 10:05 AM
02-03-2006 10:24 AM
02-03-2006 10:32 AM
02-03-2006 10:43 AM
			
    
	
		
		
		02-03-2006
	
		
		10:47 AM
	
	
	
	
	
	
	
	
	
	
	
	
	
	
 - last edited on 
    
	
		
		
		07-13-2025
	
		
		02:39 PM
	
	
	
	
	
	
	
	
	
	
	
	
	
	
 by 
				
		
		
			Content Cleaner
		
		
		
		
		
		
		
		
	
			
		
"...you should post a bug report to NI so they can take a look at it"
I agree and have already linked this thread to this months Bug List taht can be found here.
https://forums.ni.com/t5/BreakPoint/Monthly-Bugs-February-2006/m-p/318171?jump=true
NI Support has commited to monitor all of our bug postings.
Ben
02-06-2006 12:17 AM
Hello Everybody,
Thank you for alerting us of this issue. I was able to reproduce this issue, and filed a corrective action request to our R&D department.
I am sorry you are seeing this problem.
Best Regards, and thanks again,
AG,
National Instruments
			
    
	
		
		
		08-17-2006
	
		
		11:02 AM
	
	
	
	
	
	
	
	
	
	
	
	
	
	
 - last edited on 
    
	
		
		
		07-13-2025
	
		
		02:39 PM
	
	
	
	
	
	
	
	
	
	
	
	
	
	
 by 
				
		
		
			Content Cleaner
		
		
		
		
		
		
		
		
	
			
		
This was reported to R&D (# 3U5A86ET) and was fixed in LabVIEW 8.2. Here is a link to the current evaluation software download for LabVIEW. 
Thanks!