LabVIEW

cancel
Showing results for 
Search instead for 
Did you mean: 

Screen shot of a 3rd party software

Solved!
Go to solution

Hi muks,

delete these wires. You get this because in LV80 the call library function node hasn't an error connector. I created these vi's with a higher version and saved it for previous use. So you have to clean the broken wires.

 

Mike

Message Edited by MikeS81 on 06-24-2009 10:27 AM
Message 11 of 14
(623 Views)
That is exactly what i did and it is crashing my lv.
0 Kudos
Message 12 of 14
(620 Views)

Hi muks,

sorry for this. I'll check it in the evening, and if possible i send you a running LV71 or 80 version.

 

Mike

Message 13 of 14
(615 Views)
Solution
Accepted by muks

Hi mike,

 

Solved the problem. The write to bmp was creating the crash. So I replaced it with getclipboard image. In addition I changed a couple of things in vi properties and It is working perfectly fine. Thanx a lot for the help mike.

0 Kudos
Message 14 of 14
(607 Views)