LabVIEW

cancel
Showing results for 
Search instead for 
Did you mean: 

Strain gauge

I am using the strain gauge vi for labview, on the myrio.  I will be amplifying the voltage across the resistor of the strain gauge, due to the readings being so small.   Do I need to document this on the program?

Thanks

Caleb

0 Kudos
Message 1 of 9
(3,807 Views)

Hi caleb,

 

documenting what your software does is never wrong.

The same applies to any hardware that is used for a certain experiment…

Best regards,
GerdW


using LV2016/2019/2021 on Win10/11+cRIO, TestStand2016/2019
0 Kudos
Message 2 of 9
(3,796 Views)

Not really what I meant, obviously i'm going to document this, but as far as running the program, do I change any of the characterisitcs?  I am still keeping the 3.3 input voltage, just amplifiying the strain gauge for better readings.

 

Caleb

0 Kudos
Message 3 of 9
(3,783 Views)

Hi Caleb,

 

amplifying always amplifies any noise, so you may need to handle that…

Best regards,
GerdW


using LV2016/2019/2021 on Win10/11+cRIO, TestStand2016/2019
0 Kudos
Message 4 of 9
(3,780 Views)

Caleb,

I'm interested in measuring strain using a myRio.  I wonder if you could offer advice on choosing strain gauges.  For instance, which strain gauges did you use?

Thanks in advance,

 Eric

0 Kudos
Message 5 of 9
(3,678 Views)

Hi EricReynolds, 

 

The article below offers some guidance on choosing a strain guage:

https://www.ni.com/en/shop/data-acquisition/sensor-fundamentals/measuring-strain-with-strain-gages.h...

 

Catherine B.
Applications Engineer
National Instruments
0 Kudos
Message 6 of 9
(3,651 Views)

How do you use a strain gauge with the myRIO?

0 Kudos
Message 7 of 9
(3,571 Views)

Hey,

 

Here is a guide to some common myRIO projects:  https://education.ni.com/teach/resources/92/ni-myrio-project-essentials-guide 

 

However, since this is an older thread on a slightly different topic, if you want to receive good help you should start a new thread.

Britton C.
Senior Software Engineer
National Instruments
0 Kudos
Message 8 of 9
(3,543 Views)

Thank you, Catherine; this was helpful.

 

I ended up using general purpose linear pattern strain gauges from Vishay Precision Group, M-Bond 200 adhesive (to steel) and AD620 amplifiers. 

0 Kudos
Message 9 of 9
(3,524 Views)