LabVIEW

cancel
Showing results for 
Search instead for 
Did you mean: 

Write to Measurement File Defaults Back to "Save to One File"

Solved!
Go to solution

I'm trying to use the "Write to Measurment File" to make a series of files - but as soon as I hit ok it defaults back to "Save to one file". Even without running the VI it just sets itself back. I've attached files of what it looks like before I hit okay, the settings, and what happens after I close it.

 

Perhaps this is a bug?

 

Also, if you can see, I don't want the file to be called testdata__ but there is no way to change the prefix of the file because the box is greyed out. Any way to change that either?

Download All
0 Kudos
Message 1 of 3
(2,607 Views)
Solution
Accepted by tastypotato

What version of LabVIEW are you using?

 

LV2009 has some bugs with the Write to Measurement File Express VI.

 

See this thread for more information.  http://forums.ni.com/t5/LabVIEW/write-measurement-file-save-to-series-bug/m-p/1226104

0 Kudos
Message 2 of 3
(2,595 Views)

As always, thanks a bunch Ravens Fan! Trying to fix it using the f3 patch.

0 Kudos
Message 3 of 3
(2,584 Views)