Hi,
I creat an executable file with the application builder. The problem is, the window is not as large as when I starte the program in Labview. Now the Frontpanel is cut on the bottom. What is the problem ?
thanks for help
stevi
0 Kudos
Message 1 of 3
(2,649 Views)
Hello Stevi,

You should probably check your VI Properties for window size. First, make sure your front panel is sized exactly how you want it to appear. Then go to File >> VI Properties, and select Window Size from the drop-down box. Click on the "Set to Current Window Size" button. Also select "Maintain Proportions of Window for different monitor resolutions". These two selections should ensure that the VI and/or EXE will run with the desired window settings.

Hope this helps!

Liz Fausak
National Instruments
Message 2 of 3
(2,649 Views)
One other thing I noticed that LabVIEW was picky about in this situation is that when you are in development mode the front panel positioning (in terms of using the horizontal and vertical scrollbars) is stored when you File>>Save. So when you build this into an application, the front panel will move to this last saved position, even if you scrolled away from this position after saving.

Charles.