Hello:

 

Does anyone know if there are limits on the input parameters to niWLANG Set Number of Frames VI? In particular, what the limit is for the number of frames? Help on this VI doesn't say anything at all.

This is LabVIEW WLAN Generation toolkit 2.0.0

 

Thank you,

-Ilya.

 

 

0 Kudos
Message 1 of 3
(2,360 Views)
Solution
Accepted by topic author ilyak

Hi Ilya,

 

I did some 'destructive' testing on the VI and found this error message:

 

FrameLimit.PNG

 

So the limit for the number that you can set on the VI itself is 1 to 1000.  Are you wondering if there is a limitation on specific hardware as well?

Kyle A.
National Instruments
Senior Applications Engineer
0 Kudos
Message 2 of 3
(2,335 Views)

Hi Kyle:

 

No, I was wondering why this number wasn't in the specification.

Thank you for confirming.

 

-Ilya.

0 Kudos
Message 3 of 3