"DAQmx Connect Terminals.vi" missing

I just noticed you have LabVIEW 2020 f1 installed.  Any reason you are not upgrading your code to that and using the latest DAQmx???

LabVIEW Pro Dev & Measurement Studio Pro (VS Pro) 2019
0 Kudos
Message 11 of 15
(645 Views)

Attempting to install the drivers from the on-line Package Manager, I managed to install most of the version patches but the only licensed product is LabView 2011.

I listed most of the items listed under NI-MAX. While I would prefer to fix our multichannel recorder program to run on LabView 2011-2020, that is probably not possible.

The only fault upon loading is the missing "DAQmx Connect Terminals.vi" and "DAQmx Disconnect Terminals.vi" messages. I can remove the offending DAQmx. Do I remove EVERYTHING listed as "DAQmx ... 20.??"? Do I remove any of the Labview 20?? runtimes? Anything else? I appreciate all of the help!

0 Kudos
Message 12 of 15
(639 Views)

You can only have one version of DAQmx at a time.  Since you have 2020 this means you can't get the LabVIEW 2011 to work with it.

 

Can you put LabVIEW 2011 and DAQmx 14 on another PC and try that instead?

0 Kudos
Message 13 of 15
(632 Views)

It just got worse. Attempting to uninstall JUST NI-DAQmx Runtime gives "An error occurred while removing a package: ..."

Any other DAQmx package removal attempt results in a similar message.

Is there a malicious way to just delete these things?

I miss the pre-registry days when deleting a directory took care of the problem.

Binary databases are such an improvement! (sarcasm)

0 Kudos
Message 14 of 15
(629 Views)

Putting LabView 2011 on another PC is difficult as I'm not sure where the install disks or info for it is located.

0 Kudos
Message 15 of 15
(627 Views)