Hi,
I am trying to use Config_DAQ_Event_Message with event 3 or 4. I am acquiring a waveform (similar to sine wave). Now i want interrupt or callback to be fired every time input signal (AI) crosses a fixed threshold value. For example, every time signal passes -60 mV, i want to trap the event and record down the time or index at which signal crossed threshold value (-60 mV in my example). I guess i need to set trigger value 0 to my threshold. I tried doing it but i didn't get desired results. Trigger value 0 for event DAQ 3 must be in binary. does that mean i have to convert threshold (-60) to binary number? Has anyone used Config_DAQ_Event_Message? Does anyone has example code for DAQ event 3 or 4?
cheers
Niranjan