LabWindows/CVI

cancel
Showing results for 
Search instead for 
Did you mean: 

DAQmxWriteCtrFreqScalar() returns DAQmxErrorCannotUpdatePulseGenProperty (-200301) every once a while

I'm curious: does DAQmxWriteCtrFreqScalar() not use/ignore the timeout DAQmx_Val_WaitInfinitely, then?

 

I'd assume that DAQmx_Val_WaitInfinitely makes the function actually try and retry until it can update the counter and not just try once (?) and thus occasionally fail. Especially with low frequencies around 1-10 Hz.

Message Edited by CVI-User on 04-13-2010 11:15 AM
-----------------------
/* Nothing past this point should fail if the code is working as intended */
0 Kudos
Message 1 of 2
(3,083 Views)

Hi,

 

do you gat an error message or how do you know that it fails?

 

Kind regards

Carsten

0 Kudos
Message 2 of 2
(3,042 Views)