LabWindows/CVI

cancel
Showing results for 
Search instead for 
Did you mean: 

NI Update Service: communication problems

Solved!
Go to solution

Hello,

 

on different computers running different versions of Windows (XP, XP64, 7), and for different versions of the NI Update Service (from 2.0.1 up to the latest 2.2.1.7), I receive the same error message (not just today, so I tend to exclude the possibility that the service is down at NI):

 

An issue communicating with National Instruments has occurred...

 

What requirements do exist for succcessfully running it?

 

Thanks!

0 Kudos
Message 1 of 35
(7,003 Views)

Hi Wolfgang.

The service is not down at the moment.

Here is a link for this issue

http://digital.ni.com/public.nsf/allkb/ED6D02780682389986257582004FFE83 

0 Kudos
Message 2 of 35
(6,972 Views)

Hi,

 

Thanks, but in all cases (XP, 7) I have run the program as administrator...

0 Kudos
Message 3 of 35
(6,970 Views)

We have the same problem here in our offices in Denmark.

Administrator rights, version 2.2.1.7 ...

 

Any official NI status on this problem?

--
Patur Sivertsen Vase
www.hfjensen.dk
0 Kudos
Message 4 of 35
(6,948 Views)

Same thing here in Huntsville, AL.

 

Even tried wiping one computer and starting from scratch.

 

Also tried two different connections from two different providers.

 

I talked to one of the Labview techs, and the only suggestion they had was to install 2012 instead of 2011.

0 Kudos
Message 5 of 35
(6,925 Views)

NI tech asked me to disable Windows Firewall to see if that solved the problem. It didn't.

--
Patur Sivertsen Vase
www.hfjensen.dk
0 Kudos
Message 6 of 35
(6,921 Views)

Same here... Turning Window firewall off (as admin) didn't help.

 

Admittedly this is not the appropriate forum, but I don't know any better place to ask...

0 Kudos
Message 7 of 35
(6,909 Views)

Same here. NI tech support told me to run NI update to try and fix my driver issue, but update gives a message "An issue communicating with NI has occurred".....

0 Kudos
Message 8 of 35
(6,901 Views)

Hi All,

 

Can you please let me know when the error message occurs? For example, does it occur as Update Service is checking for updates, as it's downloading the updates you've selected to install, or as it's installing the updates? If you are able to see and select updates, please let me know which updates you are trying to install. You can also run Update Service from the command line to generate a log file, like this:

NIUpdateService.exe -log log.txt

The NIUpdateService.exe should be located in your Program Files\National Instruments\Shared\Update Service directory, and the log will be placed there unless you specify a different path to save the log. Please post your log here and I'll take a look. The log doesn't contain any personal information, except perhaps your Windows username on XP machines only, but it will tell me how Update Service is communicating with ni.com and evaluating updates on your system.

 

Thanks, LaRisa

LaRisa Mohr
Staff Product Support Engineer - NI Update Service
National Instruments R&D
0 Kudos
Message 9 of 35
(6,891 Views)

I am getting this error when I try to check for updates:

 

"An issue communicating with National Instruments has occured. Either this computer does not have an active Internet connection or ni.com is temporarily down. Verify your Internet connection and then click Try Again. If the problem persists, contact National Instruments."

 

Here is the contents of the log file:

 

"[2012-08-15 11:42:42Z] ----------------------------------------------------------------------

 [2012-08-15 11:42:42Z] National Instruments Update Service

 [2012-08-15 11:42:42Z] ----------------------------------------------------------------------

 [2012-08-15 11:42:42Z] NiLmClient DLL loaded successfully.

 [2012-08-15 11:42:42Z] NiLmClient DLL unloaded successfully.

 [2012-08-15 11:42:42Z] License Manager: Update Service is enabled.

 [2012-08-15 11:42:43Z] Beginning the process of checking for and evaluating updates.

 [2012-08-15 11:42:43Z] Pinging Pipeline.

 [2012-08-15 11:42:43Z] Pipeline is up.

 [2012-08-15 11:42:43Z] Finished pinging Pipeline.

 [2012-08-15 11:42:43Z] Collecting system information.

 [2012-08-15 11:42:43Z] Finished collecting system information.

 [2012-08-15 11:42:43Z] Querying ni.com for updates.

 [2012-08-15 11:42:45Z] Finished querying ni.com for updates.

 [2012-08-15 11:42:45Z] An error occurred when attempting to query ni.com for updates.

 [2012-08-15 11:42:45Z]

 [2012-08-15 11:42:45Z] ***ERROR: Errror updating Launch Condition Evaluator

 [2012-08-15 11:42:45Z]

 [2012-08-15 11:43:29Z] ----------------------------------------------------------------------"

0 Kudos