08-21-2013 10:06 AM
08-21-2013 10:26 AM
Hello razvan.ioachim,
Could you provide us with a sample that exhibits this behavior?
Thank you very much,
Ioan F. || National Instruments
08-29-2013 04:01 PM
I am in the same situations. My projects were started in CVI 2010, and compiled fine in 2012. I upgraded to CVI 2013 and they would not compile anymore. If I open them again in CVI 2012 they compile fine.
08-30-2013 12:48 AM
after discussing with NI support, we found out this happens for projects stored on network drives.
09-02-2013 05:47 AM
I've created a bug report, documenting this issue (424731). It should be fixed soon.
Best regards,
Nelu F. || National Instruments
09-25-2013 11:00 AM
I also have this issue and a similar one.
I have my projects on a network drive.
Sometimes when I get a real build failed I get no error information. Repeatidly hitting the build button will eventually display errors.
10-15-2013 09:46 AM
Same problem here. Moving the project to a local hard drive works fine. Hopefully there will be a fix soon!
10-16-2013 12:58 AM
same problem here too
10-31-2013 08:01 AM
Hello everyone,
This issue has been fixed in the 2013 Patch f1. The release notes can be found here.
Best regards,
=Nelu F. || National Instruments.