Hi guys::

              I have a problem about camera id, there are two 1394 cameras, now in my "Measurement & Automation" , they are as follows:

 

cam0: Point Gray Research Flea2 FL2-20S4C

cam1:TELI CSFV90BC3 V1.10

 

           If i do really wana to set "TELI CSFV90BC3 V1.10 " as cam0, and set "Point Gray Research Flea2 FL2-20S4C"

as cam1, what can i do?  i mean is that possible to set sepcified cam id as i want?

 

thanks

 

Message Edited by adobefree@gmail.com on 05-10-2009 03:48 AM
0 Kudos
Message 1 of 5
(4,168 Views)

It would be great if you could tell us why you want to do this. Have a look at the following articles:

Changing Interface Names of FireWire Cameras in MAX
Programmatically Finding Attached IEEE-1394 Cameras

Adnan Zafar
Certified LabVIEW Architect
Coleman Technologies
0 Kudos
Message 2 of 5
(4,155 Views)
yeh, i just mean to write the camera id fixed in program, so that the operator only need to set the camera id as i specified in test station setup introduction, instead of modify the config file
0 Kudos
Message 3 of 5
(4,152 Views)
That's OK; the first link should work for you then. As a programmer, I would recommend that you have a look at the second link and with some programming, give the operator the choice of choosing what camera he/she wants to correspond with.
Adnan Zafar
Certified LabVIEW Architect
Coleman Technologies
0 Kudos
Message 4 of 5
(4,148 Views)
Solution
Accepted by topic author adobefree@gmail.com

   I know what you mean , and also prefer the second link method, but base on some certain reason, i need the first link,

any way ,thanks a lot!