Hi:
I have a question. Can PCI 1405 be controlled by Labview 8? I am thinking of using the PCI1405 trig port to control a CCD external sync port
08-11-2008
11:08 AM
- last edited on
03-13-2025
01:24 PM
by
Content Cleaner
Hi njjz2007,
Yes, you can use this card in LabVIEW 8.0. Just be sure to have your NI-IMAQ driver installed. The latest version of the driver supports LabVIEW 8.0.
Hope this helps!
09-22-2008 04:24 PM
11-10-2009 02:26 PM
I have a question.
Since I need to connect the cable from CCD to PCI1405 card, which cable is better to use 50ohm or 75ohm? I couldn't find the specific information from the data sheet.
thanks,
11-11-2009
01:39 PM
- last edited on
03-13-2025
01:24 PM
by
Content Cleaner
Hey JasonJiang2006
The BNC cable (183882-02) recommended on the product page for the PCI 1405 is 75 Ohm, so I would recommend the same in your application.