Missing attributes (Gain, Ref. Voltage) in JAI Pulnix TM-6740 CL camera file

Hello,

 

I am using a NI PCI 1428 interface with the mentioned camera. My problem is that the corresponding icd-file available does not support all attributes that I would like to modify within LabVIEW 8.2.1. In particular, it does not contain any reference to Gain values or Reference Voltage.

 

My question now is: how can I address and adjust these parameters if they do not appear in the camera file? Has anybody come across an updated version  of the icd-file which does contain these attributes? Or this there another way for me to attack the problem?

 

Any help will be much appreciated!

 

Cheers,

Benjamin

0 Kudos
Message 1 of 3
(3,419 Views)
can you tell us the exact icd file u r having? DO u feel ur icd file is corrupted?
0 Kudos
Message 2 of 3
(3,349 Views)

The camera file available is "Pulnix TM-6740 (1428).icd" (version 6.00), which supports only some of the camera attributes. However, in the meantime I have been able to create a customized expanded version of that file using the "NI Camera File Generator" tool, which proved to be pretty useful.

 

Hence the problem can be considered as solved.

 

Thanks anyway,

Benjamin