06-15-2009 05:06 AM
Hello,
I am using a NI PCI 1428 interface with the mentioned camera. My problem is that the corresponding icd-file available does not support all attributes that I would like to modify within LabVIEW 8.2.1. In particular, it does not contain any reference to Gain values or Reference Voltage.
My question now is: how can I address and adjust these parameters if they do not appear in the camera file? Has anybody come across an updated version of the icd-file which does contain these attributes? Or this there another way for me to attack the problem?
Any help will be much appreciated!
Cheers,
Benjamin
07-15-2009 01:32 AM
07-15-2009 04:02 AM
The camera file available is "Pulnix TM-6740 (1428).icd" (version 6.00), which supports only some of the camera attributes. However, in the meantime I have been able to create a customized expanded version of that file using the "NI Camera File Generator" tool, which proved to be pretty useful.
Hence the problem can be considered as solved.
Thanks anyway,
Benjamin