Need to Create an ICD file for RS-343 (875 line) Standard Analog Video

I need to create an ICD file for RS-343 (875 line) standard analog video. I am using a PCI-1409 and will soon be using a PCI-1410. I tried speaking with NI tech support and they encouraged me to try and modify the RS-170 ICD file but could not give me any specifics on paramters or syntax. After searching these forums it appears that this question has been asked before but at a higher resolution and was subsequently dimissed because the presumed pixel clock of the RS-343 was above the supported 40MHz of the PCI-1409/1410. The RS-343 I am trying to interface is the standard military monochrome 875-line and has the following general specifications...

Active Line Length: 960 pixels, 30.99 usec.
Vertical Active Height: 802 lines
Nominal Line Period (total width): 1180 pixels, 38.10 usec.
Lines Per Frame: 875 lines
Pixel Clock: 30.975000 MHz, period = 32.284100
nsec. Horizontal Line Frequency: 26.250 KHz
Horizontal Sync Duration: 85 pixels, 2.74 usec.
Horizontal Back Porch Duration: 105 pixels, 3.39 usec.
Horizontal Front Porch Duration: 30 pixels, 0.97 usec.
Vertical Front Porch Duration: 3540 pixels, 3.0 lines, 0.11 msec
Vertical Sync Duration: 3540 pixels, 3.0 lines, 0.11 msec
  Sync Pulse Duration: 530 pixels, 17.11 usec
  Sync Pulse Count: 6
Vertical Back Porch Duration: 36580 pixels, 31.0 lines, 1.18 msec
VWALK to ACTIVID duration: 10640 pixels, 9.016949 lines
Frame Frequency: 30 Hz Interlaced, 2 Fields


If anyone out there can lend a hand on this I would be much appreciated.
Thanks.

0 Kudos
Message 1 of 5
(6,204 Views)
In this thread.Will holmes reply be of some use to you?
0 Kudos
Message 2 of 5
(6,177 Views)
No, unfortunately not.
I found that thread earlier and all that Holmes does is state that a pixel clock of 68.5 MHz is not supported by the PCI-1409/1410 which have a maximum pixel clock of 40 MHz. My RS-343 video source has a pixel clock of about 31 MHz.
0 Kudos
Message 3 of 5
(6,164 Views)
Hello J Mazzetta,

I just wanted to let you know that from here on, we will correspond with you through the service request that you have created with us. We always maintain one service request per issue to enable easy communication and better efficiency for support.
Vivek Nath
National Instruments
Applications Engineer
Machine Vision
0 Kudos
Message 4 of 5
(6,148 Views)

Was this ever solved?  Can a 1409 frame grabber capture RS-343?

 

- Brad?

0 Kudos
Message 5 of 5
(5,567 Views)