Machine Vision

cancel
Showing results for 
Search instead for 
Did you mean: 

Using Vision Assistant calibration for post processing

Solved!
Go to solution

This is the error I am getting:

Error -1074396120 occurred at IMAQ Copy

0 Kudos
Message 11 of 16
(1,369 Views)
Solution
Accepted by Vishwarath1990

Try placing down an IMAQ Create.vi and then wiring the buffer reference into the Image DST input of the Vision Assistant Express VI. This creates a new image buffer for any alterations made to the image type within the Vision Assistant Express VI.

Matt G.
Product Manager
National Instruments
Message 12 of 16
(1,361 Views)

Hi Matt, Thanks for your reply. Is there any reference VI or examples to understand this better?

 

0 Kudos
Message 13 of 16
(1,358 Views)

Hi Matt. I got that. Now my VI is working fine

0 Kudos
Message 14 of 16
(1,351 Views)

Hi Matt. I got that. Now my VI is working fine

0 Kudos
Message 15 of 16
(1,345 Views)

Awesome! I'm glad to hear that worked!

Matt G.
Product Manager
National Instruments
0 Kudos
Message 16 of 16
(1,332 Views)