Hi there,
I can generate output using the 'Gen Dig Pulse Train Continuous'
example vi on both counter terminals (cntr0, cntr1). However when wired
together and a pulse generated from one and counted at another using
the 'Count Digital Events' example vi, nothing is ever counted.
I can generate analog, digital and counter pulse output using the
DAQ-mx assitant fine on these and other terminals but not any kind of
read task using the assistant.
Output is verified using a multimeter (at low frequencies). Input does not seem to be registered regardless of frequency.
The generated pulse are 5V, however when wired to the other count
terminal this drops to around 2.2V suggesting that perhaps the read
terminal is earthed. I am sure that the terminals I am using are cntr0
and cntr1 since I can measure output from either count terminal when
selected in 'Gen Dig Pulse Train'.
What could the problem be?
regards,
Brendan Arnold