Manually assert PXI RTSI triggers?
Manually assert PXI RTSI triggers?
Bob Rafuse
Member
11-25-2002
09:35 AM
Options
Mark as New
Bookmark
Subscribe
Mute
Subscribe to RSS Feed
Permalink
Print
Report to a Moderator
Sorry if this is a stupid question...
Is there a way to programmatically assert a RTSI trigger line in a PXI cage?
I want to debug my DAQ triggered acquisition setup without involving the
hardware that normally generates the trigger.
Thanks,
---
Bob
0
Kudos
Message
1
of 2
(2,528 Views)
Reply
Re: Manually assert PXI RTSI triggers?
Filipe A.
Active Participant
11-26-2002
10:20 AM
Options
Mark as New
Bookmark
Subscribe
Mute
Subscribe to RSS Feed
Permalink
Print
Report to a Moderator
Hello;
Unfortunately, that can't be done.
One doesn't have any control over the RTSI lines themselves, the RTSI lines are only for routing signals.
Regards
Filipe A.