Multifunction DAQ

cancel
Showing results for 
Search instead for 
Did you mean: 

NI 9205

This is my first post i always used the usb series van NI, i want to migrate to the compact daq series. I got a test package from NI that involves the Hi speed usb carrier NI USB-9162 and a Compact daq the NI 9205. Some further information im running Labview 2010 student license, and installed the NI device drivers (default) from august 2010.

 

My problem is that i cant find anny card in labview, windows (7) installed driver for the usb carrier. If only the usb carrier is connected the led is constantly burning, if the 9205 is put in the carrier the led is flashing.

 

 

0 Kudos
Message 1 of 2
(3,704 Views)

Dear Mambow,

 

thank you for your post. We had some mail contact regarding this issue, I just wanted to answer your post so that developers who are seeking through the forum to their answer with a similar problem can benefit from your post.

This module will not work in the carrier, a complete list of which c series module works in what chassis or carrier can be found under this link.

 

Best regards,

Martijn S
Applications Engineer
NI Netherlands
0 Kudos
Message 2 of 2
(3,643 Views)