05-14-2008 02:02 AM
05-15-2008 05:01 AM
05-15-2008 10:45 AM
05-16-2008 01:56 AM
05-16-2008 10:14 AM - edited 05-16-2008 10:18 AM
Hey Marcel,
For M-Series, all 4 DACs share the same FIFO, data transfer bus and output clock. So if you are generating on all four channels, a sample is sent to DAC1 and latched in, then samples are sent to the rest in the same manor. All four DACs then generate on the same output clock. While the DACs are loaded with new values they retain the value from their previous update.
The important takeway is that all output channels are updated on the same clock - even if the transfer from the FIFO occurs at different times. Hope this helps,
Andrew S
Multifunction DAQ Product Support Engineer