Multifunction DAQ

cancel
Showing results for 
Search instead for 
Did you mean: 

getting error "200288"...

Solved!
Go to solution

Dear all LabVIEWers,

 

I dont know what is wrong with this VI, on running its throwing an error-200288.

please help me out.

 

Regards.

moderator1983


I am not allergic to Kudos, in fact I love Kudos.

 Make your LabVIEW experience more CONVENIENT.


0 Kudos
Message 1 of 3
(4,194 Views)
Solution
Accepted by topic author moderator1983

Hi Moderator1983!

 

According to this link:

 

http://digital.ni.com/public.nsf/allkb/BFCE83133C0ECAD786256E6000814B68?OpenDocument

 

The issue seems to be related to a DAQmx Stop. I added the stop task VI to your VI and was able to avoid the error. Im attaching an image for this.

Hope this helps.

 

Have a great day!!

0 Kudos
Message 2 of 3
(4,181 Views)

That's perfect solution...

 

As I'm a novice LabVIEWer, this was a big problem for me...

 

many thanks for replying and giving the solution...


I am not allergic to Kudos, in fact I love Kudos.

 Make your LabVIEW experience more CONVENIENT.


0 Kudos
Message 3 of 3
(4,164 Views)