03-12-2010 08:13 AM
Hi !
I set the function generator to 1kHz, 25%, starting the simulation, its ok, but when I click to the up arrow on the duty cycle to increase it by one percent, the output of the function generator is switched to 100-26 = 74 percent. And from that point, is working inverted. (ver: 11.0.278 )
Solved! Go to Solution.
03-15-2010 06:34 AM
Hi
I have just checked it and you're right - I got the same behavior. It seems like a bug in our software. I will contact our developers to see what they think about it. I will let you know if we can do something about it.
Thanks for identifying this!
03-15-2010 12:30 PM
Hello
I have just heard back from our developers. The issue has been reproduced and entered into their bug reporting system with ID: 117065. The fix will be included in one of the future versions. There is no direct workaround though. If you have an educational version of Multisim, you can use the generator coming with NI-ELVISmx drivers - this one works fine. Please let me know if there is anything else I can help you with.
03-15-2010 02:39 PM
Thank You for the quick reply !
I am happy to help improving this awesome software.
12-14-2011 02:51 AM
hi,i'm izuan..
how can i,design function generator using Labview?
can u give me,example to design function generator...help me
12-15-2011 01:35 AM
Hello Izuan,
this thread is resolved and its on a different topic. Please start a new thread and ask you question there to keep forum clean and healthy.