NI TestStand

cancel
Showing results for 
Search instead for 
Did you mean: 

CommonResults type conflict

I have a test system at another location that has developed a problem. When the test application is launched the following error message appears ''Type "CommonResults" is invalid because it conflicts with the existing type of that name. This occurs before the SequentialModel.seq file is loaded. This system only has a deployment license so I'm not sure what happened. Does anyone have an idea what happened or a way to resolve this?

0 Kudos
Message 1 of 5
(3,746 Views)

You could try using the Types Differ Tool found at the following location.

 

https://decibel.ni.com/content/docs/DOC-4070

Regards
Ray Farmer
0 Kudos
Message 2 of 5
(3,741 Views)

Thank you for your response. I am not familiar with that tool. Would it be useful for a remote test site that only has a development license?

0 Kudos
Message 3 of 5
(3,733 Views)

Hi LabTech,

 

I took a look at the tool and as far as the I could see you can use it on a deployment machine. You should be able to run the tool remotely once you all are ont he same network. Whhich means that you put the tool on the target machine and you can remote in to operate it. I hope that this helps.

 

Regards,

 

Perry S.

Applications Engineer
National Instruments
0 Kudos
Message 4 of 5
(3,716 Views)

I'm having the same conflict.  How would I fix this in 2019?

0 Kudos
Message 5 of 5
(2,148 Views)