10-03-2005 08:54 AM
10-03-2005 09:47 AM
10-03-2005 09:51 AM
08-11-2009 08:33 AM
I am using TestStand 4.2, and this does not work for me. The pre-expression statement Step.TimeToWait = <variable> is ignored and the time to wait is always the default value.
I ended up having to put a statement step before the message popup step with the statement RunState.NextStep.TimeToWait = Locals.variablename.
08-13-2009 09:58 AM
I just tried this in TestStand 4.1 and it (usning the pre-expression) works. The key is that the "Timeout Button" must be set to a visible button number and not to None or a button with no text assigned.
[Wow, the TS version selector takes a while to run...]
Also works in TS 4.2.