Hello everyone,

 

I am trying to create my own custom step type.Everything work fine(Custom Step) but when i restart TestStand, step type removed from Types. Although, This INI file is already in a Type Palettes. "Mode" Step highlighted in given picture

 

anyone has idea ?

Kuddo welcomed
CLAD-CTD
0 Kudos
Message 1 of 7
(3,040 Views)

Hi,

 

Could you take a wider screenshot that has the whole Types Window?

 

Are you creating this step under the Sequence File you are working in, or in the My Types.ini file?

 

Nico

 

 

--------
Nico
Systems Engineer

Certified TestStand Architect Certified LabVIEW Architect

0 Kudos
Message 2 of 7
(3,037 Views)

I am working on my own load.INI file not in sequence. check picture

Kuddo welcomed
CLAD-CTD
0 Kudos
Message 3 of 7
(3,035 Views)

Hi,

 

If you create and save this in either the <TestStand Public>\Components\TypesPalettes  or the <TestStand>Components\TypesPalette folder it should load.

 

Is the ini file stored in either of these locations?

 

Nico

--------
Nico
Systems Engineer

Certified TestStand Architect Certified LabVIEW Architect

0 Kudos
Message 4 of 7
(3,024 Views)

<TestStand Public>\Components\TypesPalettes   these location 

Kuddo welcomed
CLAD-CTD
0 Kudos
Message 5 of 7
(3,015 Views)

Sorry about the slow reply.

 

This is really strange. Does the same happen if you create the step in any of the other files? If you create it under a sequence file does it stay when you save the sequence?

 

Can you create another and share the ini file?

 

Nico

--------
Nico
Systems Engineer

Certified TestStand Architect Certified LabVIEW Architect

0 Kudos
Message 6 of 7
(2,971 Views)
Solution
Accepted by topic author Gab008

its solved !!

i think its because in step properties, there is option Attach to this file(Type Properties Dialog Box). if i tick this option when creating custom step then after restarting TS, step will remain there.

Kuddo welcomed
CLAD-CTD
0 Kudos
Message 7 of 7
(2,968 Views)