How can I eliminate the [In] and [Out]'s in a TestStand ATML report?

I am using TestStand 4.1.1.  When I generate ATML reports I get the [in] and [out] printed with my input and output parameters.  How can I eliminate the [in] and [out]'s from my test report?  Thanks.
0 Kudos
Message 1 of 3
(3,048 Views)

epsilon-delta,

 

Let me look into this tomorrow and get back with you then.  There is a fairly easy way to do this if you were using HTML reporting, and there's a workaround for ATML reporting, but I want to make sure there is not an easier way before we look into this workaround.

Eric B.
National Instruments
0 Kudos
Message 2 of 3
(3,029 Views)

epsilon-delta,

 

 We can edit your xsl stylesheet that sets the formatting for your ATML report.  The new stylesheet is attached to this post.  This adds a check to the stylesheet for the ID and the name of results to see if there is an [In] or [Out] at the end of the ID or name.  If so, it displays a shortened string.  Otherwise it displays the full ID or name.  The new code is at lines 201-213 and 420-432.  You can place this in your TestStand public folder in the Models folder: C:\Documents and Settings\All Users\Documents\National Instruments\TestStand 4.1.1\Components\Models , and then set your report settings to use this stylesheet instead.