06-15-2010 05:37 AM
Hi All
I have the problem if report generation enabled.
If the sequence test failed the program crashes with errors or close itself. If passes the sequense continue running to next uut. The problem exists in html and in ascii format both.
Report generation disabled solve the problem but I need the report option.
Help please
06-15-2010 06:11 AM
Hi,
What Teststand version are you using?
Are you using the default Process Models and what process model are you using?
Are you using the default report generation sequences?
regards
Ray Farmer
06-15-2010 06:24 AM
Hi
Thank you for the quick response
version 2.0.1
sequential model
default report generation sequences.
06-15-2010 06:42 AM
One differense. We use our model to get S/N and part number of UUT
3 fields instead of 2 regular teststand fields
06-15-2010 07:00 AM
You said you were using the default report generation, how are you handling the extra field.
Also I notice you have Insert Graph, do you have a graph inserted?
regards
Ray Farmer
06-15-2010 07:02 AM
Hi,
Have you tried using the option 'Sequence' for 'Select a Report Generator for Producing the Report Body' instead of 'DLL'
Regards
Ray Farmer
06-15-2010 07:18 AM
ok I''ll try to remove the graph and to switch it to sequence.
Maybe additional options to check ?
06-15-2010 01:51 PM
06-16-2010 03:44 AM
Actually nothing
or operator interface close himself if sequense run in operator mode.
or teststand error 170xx and i need to close it if in debug mode.
06-16-2010 05:45 PM
Hello Ilanx,
Have you tried running one of the example programs with the report option selected? If so do you receive the same error? I was also wondering if you could post a screenshot of the error you are getting. Have a great day!
Best Regards,
Adam G