NI TestStand

cancel
Showing results for 
Search instead for 
Did you mean: 

Sequence Editor fails to start

Solved!
Go to solution

Wondering if anybody has seen something like this

Just before I start digging into config files...

 

Oli_Wachno_0-1697542575878.png

Upon pressing OK, SeqEdit stays active / doesn't crash,  but no login / logout possible, so no action possible other than closing SeqEdit

 

Cheers

Oli

0 Kudos
Message 1 of 4
(1,175 Views)
Solution
Accepted by topic author Oli_Wachno

https://knowledge.ni.com/KnowledgeArticleDetails?id=kA03q000000wwyACAQ&l=de-DE

 

The part about deleting <TestStand_LocalAppData> contents did the job.

 

Could've googled before asking, sorry!

Message 2 of 4
(1,153 Views)

Hi, 

 

To help debug and resolve this issue, do you still have the old files from LocalAppData? Can you post them here?

 

Thank you,

Anand Jain

NI

Message 3 of 4
(1,119 Views)

Hi Anand,

 

please find attached an archive containing SeqEdit.xml and layout_current.bin

 

Toying around a little bit, I found out that deleting layout_current.bin already helps, so something must be in there thats offending SeqEdit

 

Thanks

Oli

Message 4 of 4
(1,092 Views)