04-18-2013 12:24 PM
Hi,
Whenever I try to insert an action as a step in NI TestStand, I get the following exception --
I tried to search on these boards but could not find such an issue. This problem started since I upgraded to LV 2012 Developer suite (32 bit) from LV 2011 recently. I'd appreciate any help/suggestions.
Thank you.
Capgen
Solved! Go to Solution.
04-18-2013 01:46 PM
Capgen,
Have you tried this on another pc?
I had this exact same issue with a particular dev pack that was released where the LabVIEW and TestStand versions did not work together. I cannot recall if this was 2012 DS1 or earlier but it stung me a couple of times.
I believe my work around at the time was to use 2012 LabVIEW but 2011 TestStand. Do you have 2012 DS2?
Can anybody add more detail to the above?
-Steve
04-18-2013 03:21 PM
Steve,
Thanks for the suggestion.
I don't have TestStand 2011. On a quick search I could not find previous versions of NI TestStand on NI websites either.
Do you are someone here know if older versions of TestStand are available for download?
Thanks.
Capgen
04-18-2013 04:31 PM
04-18-2013 04:59 PM - edited 04-18-2013 05:01 PM
Hi Steve,
I still see the same exception in TestStand2010SP1 (4.5.1) while using it with LV 2012. I should probably revert to LV 2011. Do you have any other ideas I could try?
I have not tried it on another machine yet (don't have one.)
Capgen
04-18-2013 07:24 PM
The problem is now fixed. Here is the TS/LV combination that worked for me.
TS = 4.2.1
LV = 2012
Thank you.
Capgen
04-19-2013 04:35 AM
I tried with TS 2010 SP1 and LV 2012.
Checked the example did not face any issue.
In any case did you try to install the udpates ( just run NI service updates).