NI PXIe-8108 reboot due to system error

I have a NI PXIe-1082 chassis with a NI PXIe-8108 controller. 

when I power up the system it fails to boot. The system starts LabVIEW Real-Time executive.

It reaches

Initializing network...

Device 1 - MAC addr: 00:80:2F:12:99:C3 - 169.254.201.85 / 16 (primary - static)

 

Reboot due to system error.

System state: Safe Mode (software Error)

 

I have attached the ni_support.zip report from MAX.

 

How should I fix this software error?

 

Richard

0 Kudos
Message 1 of 5
(6,870 Views)

Hi,

 

 Is this a fresh install of LabVIEW RT? Before this error, was the real time target working properly?

 

Regards,

Miguel Fonseca

Applications Engineer

National Instruments

0 Kudos
Message 2 of 5
(6,854 Views)

 

Miguel,

 

The real time target was working prior to this error.

 

Richard

0 Kudos
Message 3 of 5
(6,841 Views)

Hi,

 

I've doing some research but I haven't found the cause of this error. However I've found some cases that are pretty similar to this one and the solution proposed was to reformat your real time target from MAX.

Could you please try to reformat your device? You have to restart your target into safe mode. Once the boot process is completed, open MAX, find your device (right click on it) and format your disk.


Regards,


Miguel Fonseca

Applications Engineer

National Instruments

Message 4 of 5
(6,830 Views)

Miguel,

 

I have formated the disk and reloaded the software.

 

All good now.

 

Richard

0 Kudos
Message 5 of 5
(6,811 Views)