Peer-to-peer custom device only works on the PXIe-8821 CPU. We have a custom device for peer-to-peer communication between the FPGAs. This works with the PXIe-8821 CPU,
but if I install the PXIe-8862 or PXIe-8881 CPU with the same way as the 8821, no data is transferred peer-to-peer.
Do I have to consider the type of the custom device in the Custom Device project? I've only entered an RT PXI Linux X64 target without a specific type.
Does anyone have any ideas?
VeriStand 2020 R6
NI Linux Real-Time x64 6.1.38-rt12
10-21-2025 07:55 PM
What version of driver are you using?
The only difference between these controllers I can think of is the minimum PXI Platform Service version.
Perhaps you can try if these hardware combination can work in pure LabVIEW ADE?
10-22-2025 07:15 AM - edited 10-22-2025 07:15 AM
The latest PXI Platform Service driver, 23.8, is already installed. It's the same on both.