03-25-2014 04:15 PM
I have DiAdem 2012 SP1 installed. All of a sudden every time i try to open it i get an error message saying "Could not Initialize USI Report" see attached.
I have tried uninstalling and re-installing DiAdem but it made no difference.
I tried following the instructions in this post
http://forums.ni.com/t5/DIAdem/Errorcode-1906/m-p/810319/highlight/true#M9682
but when i double click the URI files i get an error message (attached). My URI's are also in C:\Program Files (x86)\National Instruments\Shared\USI\Bin since i am on a 64 bit.
I have Windows 7 64bit, LV2013 and a lot of other NI software installed.
03-26-2014 03:32 AM
Looks like there is something wrong or missing in your installation.
Can you please check usiReg.exe for missing dependencies as described below:
1. Download and unzip Dependency Walker: http://www.dependencywalker.com/depends22_x86.zip
2. Start Dependency Walker and open usiReg.exe: C:\Program Files (x86)\National Instruments\Shared\USI\Bin\usiReg.exe
3. Save the Dependency Walker Image and post it here or attach a screenshot of the module tree
03-26-2014 03:45 PM
Hi usac,
I have attached the image.
Thanks
03-26-2014 03:47 PM
another one
03-27-2014 10:19 AM
Thanks a lot for the images. My best guess is that the 32bit and 64bit binaries are mixed.
Can you please post the content of two registry keys as follows:
1. Open regedit
2. Navigate to HKEY_LOCAL_MACHINE\SOFTWARE\National Instruments\Common\Installer\
3. Post the content of NISHAREDDIR64
4. Navigate to HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\National Instruments\Common\Installer\
5. Post the content of NISHAREDDIR
03-27-2014 11:56 AM
The NISHAREDIR64 Contenets are
C:\Program Files\National Instruments\Shared\
I do not have NISHAREDIR in HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\National Instruments\Common\Installer
Thanks
03-28-2014 08:39 AM
That's curious, does the folder itself exist?
HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\National Instruments\Common\Installer
If yes, can you please post the content as shown in the attached image?
03-28-2014 10:48 AM
Sorry, my bad i was looking in the wrong place. The contents of NISHAREDIR are:
C:\Program Files (x86)\National Instruments\Shared\
04-07-2014 03:39 PM
Hi USAC,
Any ideas what might be happening?
Thanks
04-15-2014 02:54 AM
Sorry for the late response. We were trying to reproduce the error without success until now.
Therefore we would like to ask you to perform the following steps:
Check dependencies:
1. Start Dependency Walker and open usiEx.dll: C:\Program Files (x86)\National Instruments\Shared\USI\Bin\usiEx.dll
2. Switch on full path (F9) and post the saved Dependency Walker image here.
Check registry entries:
1. Open regedit
2. Navigate to HKEY_LOCAL_MACHINE\SOFTWARE\National Instruments\Common\USI\
3. Post the content of binDir
4. Navigate to HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\National Instruments\Common\USI\
5. Post the content of binDir
If possible, please post the zipped contents of the USI bin dir:
C:\Program Files (x86)\National Instruments\Shared\USI\bin\
Thanks a lot