The internal DIAdem data organization returned an initialization error

Solved!
Go to solution

Hello,

 

I uninstalled and installed again ( for the 4th time) and now it's working.

 

Thank you for your help on this

0 Kudos
Message 11 of 16
(1,817 Views)

Hi, I have nearly the same Error. Every time I start up my PC I get 2 Error.

 

1.
DataFinder.exe - Einsprungpunkt nicht gefunden
---------------------------
Der Prozedureinsprungpunkt "?MapAttributeNameR@ToIEntityImpDa@DataCache@@QBEABV?$StringBase@GDG@dsc@ni@@ABV345@@Z" wurde in der DLL "dacasr.dll" nicht gefunden.

2.

National Instruments DataFinder
---------------------------
The DataFinder cannot start due to an internal error.

usi not correctly initialized

 

What can I do to clear this Error?

0 Kudos
Message 12 of 16
(1,672 Views)

What kind of software from National Instruments do you have installed?

It looks like there is a mix of incompatible software versions installed on your computer.

0 Kudos
Message 13 of 16
(1,664 Views)

Hello, I have done some screenshots for you.

I can't see any mix, and you? And I don't know what "Visa Shared Components" is. Is this from NI?

Thanks

0 Kudos
Message 14 of 16
(1,649 Views)

Thanks a lot for the screenshots. Please have a try and run a Repair on the DataFinder Toolkit 2010. The Toolkit contains all components which, from my perspective, are responsible for the errors you observer.

 

RepairDFTK.png

 

Please let me know if this does not help.

0 Kudos
Message 15 of 16
(1,644 Views)

usac,

thank you very much, thats was the solution.

0 Kudos
Message 16 of 16