Machine Vision

cancel
Showing results for 
Search instead for 
Did you mean: 

how the carmera open via imaqdx use so long time up to 71S?

Solved!
Go to solution

Basler acA2500-14gc  camera       how the carmera open via imaqdx use so long time up to 71S?

is there some setting in camera need to be modify?

imaq.jpg

0 Kudos
Message 1 of 5
(3,673 Views)

Have you tried updating IMAQdx? New versions contain updated versions of the standard GenApi/GenICam component that address some performance issues loading the camera's XML file. Unfortunately the Basler cameras have some pretty complex XML files and so when they are used with older GenApi versions they are quite slow to load.

 

Eric

0 Kudos
Message 2 of 5
(3,665 Views)

my imaqdx is 3.4 now

0 Kudos
Message 3 of 5
(3,658 Views)
Solution
Accepted by topic author Hugo_ye

3.4 is extremely old. You probably want to update the 4.0 which is part of the latest Vision Acquisition package:

 

http://joule.ni.com/nidu/cds/view/p/id/2975/lang/en

 

Eric

0 Kudos
Message 4 of 5
(3,652 Views)

Thank you very much, BlueCheese !

the issue is closed, ths!

0 Kudos
Message 5 of 5
(3,644 Views)