Multifunction DAQ

cancel
Showing results for 
Search instead for 
Did you mean: 

TROUBLE BUILDING VISA Configure Serial Port .vi

My application Builds fine in LV 7.0, however in LV 8.2 using the Project folder, I receive the following :
 
Polymorphic VIs cannot be used as Startup/Exported or Dynamic VIs for applications or shared libraries.
C:\NEM DS18S20 TEST-8.20\NEM0775B\NEM0775B.llb\VISA Configure Serial Port

Visit the Request Support page at ni.com/ask to learn more about resolving this problem. Use the following information as a reference:
Error 1035 occurred at ABAPI Dist Check if PolyVI.vi -> ABAPI Load All Libraries And VIs.vi -> ABAPI Dist Build LLB Image.vi -> ABAPI Copy Files and Apply Settings.vi -> EBEP_Invoke_Build_Engine.vi -> EBUIP_Build_Invoke.vi -> EBUIP_Build_Rule_Editor.vi -> EBUIP_Item_OnDoProperties.vi -> EBUIP_Item_OnDoProperties.vi.ProxyCaller
Possible reason(s):
LabVIEW:  Operation is invalid for this type of VI.
 
I am using, Polymorphic VI = VISA Configure Serial Port to configure my serial port and then count bytes received for certain serial Port CmDs.
 
I am only using the Serial Port (Instr) of the Polymorphic VI.  What is the easiest way to BUILD a application that will work????   I've used this method back to 4.1.  This new BUILD/PROJECT METHOD is not good.
 
Please Help
Brian Campbell
 
0 Kudos
Message 1 of 3
(3,196 Views)
Hi Brian,

I hope you are doing well today! Implement the suggestions provided in the following post:
application build problems with polymorphics

If these don't help, be sure to repost and include comments about what happened when you tried those steps.
Adnan Zafar
Certified LabVIEW Architect
Coleman Technologies
Message 2 of 3
(3,177 Views)

Thank you,

 

I went to Advanced options and can build OK now.

 

Thank you

0 Kudos
Message 3 of 3
(3,160 Views)