11-01-2012 06:32 PM
New to Multi-sim -
Is there a tutorial for the intended purpose of using off-page connectors and not global?
1. Suppose nets need to be connected to a number of sheets, should global connectors be used or should off-page connectors of same name be used. What the intent of the two?
2. Can global connectors be connected to buses for linking to sheets? or should an off-page connector be connected to a bus?
An explanation should be entered into HELP, and perhaps a tutorial.
Thanks
Solved! Go to Solution.
11-05-2012 11:44 AM
Hi johnkimura,
In the help file, you can search for connector types and you will find the help documentation about the connectors. The difference between an off page and a global connector is that an off page connector is only visible on the same level in the hierarchy. What this means is that if you are in one sub-circuit, you can use an off page connector to connect to another sub-circuit at the same level.
For Bus lines, you need to use the bus off page connector.
Hope this helps.