10-13-2016 04:40 AM
Hi all,
I'm new to TestStand, so I have simple question which might boring you but I cannt find the solution.
In my Main Sequence I have say 50 steps. If one step failed the next step will be executete (by deafult).
What can I do to stop the execution of the following steps if one step failed. I wish that the sequencer goes to Cleanup directly insteed call the next step in the Main Sequence.
Any simple hint is appreciated.
Axel
Solved! Go to Solution.
10-13-2016 04:53 AM
Hi,
You can set the sequence to goto cleanup on sequence failure by setting:
Configure >> Station Options >> Immediately Goto Cleanup on Sequence Failure
Also check that the steps will cause a sequence failure on a step failure, by configuring:
Step Settings >> Step Failure Causes Sequence Failure
I hope this helps,
Charlie Rodway | Principal Software Engineer | Certified TestStand Architect (CTA)
Computer Controlled Solutions Ltd | NI Silver Alliance Partner | GDevCon#1 Sponsor