Machine Vision

cancel
Showing results for 
Search instead for 
Did you mean: 

basler 相机 aca 1600 连接问题,那位大侠能给出点主意

201220320816627624.jpg

0 Kudos
Message 1 of 11
(4,586 Views)

Your question must be: Why do I get this error?

Just check this:

Is your ethernet card Gigabyte?

Does your ethernet card support Jumboframes?

Did you enable Jumboframes?

Did you turn off your firewall?


Regards

NTA_LabView_certified_Developper.jpg
0 Kudos
Message 2 of 11
(4,585 Views)

There is a solution to the Test Packet Time Out Error located at http://digital.ni.com/public.nsf/allkb/8D9A975B04F66B728625768900805A21.

 

 

 

Robert Eastlund
Graftek Imaging, Inc.
Phone: (512) 416-1099 x101
Email: eastlund@graftek.com
0 Kudos
Message 3 of 11
(4,581 Views)
my ethernet card is Marvell Yukon 88E8057 PCI-E Gigabit Ethernet.how can i know my ethernet card support Jumboframes. my ethernet card setting like this
0 Kudos
Message 4 of 11
(4,571 Views)

setting like this11.jpg

0 Kudos
Message 5 of 11
(4,566 Views)

Select the Test Packet Enabled attribute and set it to be disabled the soft show a error

error.jpg

 

 

my soft seeting like this

 

0 Kudos
Message 6 of 11
(4,564 Views)

Hello,

In you NIC property panel, set the jumboframes to the highest value (ie about 9000bytes). 

Regards

NTA_LabView_certified_Developper.jpg
0 Kudos
Message 7 of 11
(4,556 Views)

大哥,你的这个相机搞定了吗?我现在手上也有一个,我是个初学者,可以指点一二吗?恭候

0 Kudos
Message 8 of 11
(4,283 Views)

@Robert_Eastlund wrote:

There is a solution to the Test Packet Time Out Error located at http://digital.ni.com/public.nsf/allkb/8D9A975B04F66B728625768900805A21.

 


Hi Robert, this only applied to a very small number of the Scout series with a very specific firmware. The Ace and any other cameras do not have any bugs with the Test Packet functionality that require it to be disabled.


Eric

0 Kudos
Message 9 of 11
(4,281 Views)

问题已经解决。最后使用labview2011连接相机就没有再出现问题。

0 Kudos
Message 10 of 11
(4,274 Views)